Collect HP ProCurve logs

Supported in:

This document explains how to ingest HP ProCurve logs to Google Security Operations using the Bindplane agent.

HP ProCurve is a line of network switches that generate syslog messages for authentication events, configuration changes, network activity, and system events. The parser extracts fields from syslog-formatted logs, parses key-value pairs and descriptions, and maps them to the Unified Data Model (UDM).

Before you begin

Make sure you have the following prerequisites:

  • A Google SecOps instance
  • Windows Server 2016 or later, or Linux host with systemd
  • Network connectivity between the Bindplane agent and the HP ProCurve switch
  • If running behind a proxy, ensure firewall ports are open per the Bindplane agent requirements
  • SSH access to the HP ProCurve switch

Get Google SecOps ingestion authentication file

  1. Sign in to the Google SecOps console.
  2. Go to SIEM Settings > Collection Agents.
  3. Download the Ingestion Authentication File.
  4. Save the file securely on the system where the Bindplane agent will be installed.

Get Google SecOps customer ID

  1. Sign in to the Google SecOps console.
  2. Go to SIEM Settings > Profile.
  3. Copy and save the Customer ID from the Organization Details section.

Install the Bindplane agent

Install the Bindplane agent on your Windows or Linux operating system according to the following instructions.

Windows installation

  1. Open Command Prompt or PowerShell as an administrator.
  2. Run the following command:

    msiexec /i "https://github.com/observIQ/bindplane-agent/releases/latest/download/observiq-otel-collector.msi" /quiet
    
  3. Wait for the installation to complete.

  4. Verify the installation by running:

    sc query observiq-otel-collector
    

    The service should show as RUNNING.

Linux installation

  1. Open a terminal with root or sudo privileges.
  2. Run the following command:

    sudo sh -c "$(curl -fsSlL https://github.com/observiq/bindplane-agent/releases/latest/download/install_unix.sh)" install_unix.sh
    
  3. Wait for the installation to complete.

  4. Verify the installation by running:

    sudo systemctl status observiq-otel-collector
    

    The service should show as active (running).

Additional installation resources

For additional installation options and troubleshooting, see the Bindplane agent installation guide.

Configure the Bindplane agent to ingest syslog and send to Google SecOps

Locate the configuration file

  • Linux:

    sudo nano /etc/bindplane-agent/config.yaml
    
  • Windows:

    notepad "C:\Program Files\observIQ OpenTelemetry Collector\config.yaml"
    

Edit the configuration file

  • Replace the entire contents of config.yaml with the following configuration:

    receivers:
        udplog:
            listen_address: "0.0.0.0:514"
    
    exporters:
        chronicle/hp_procurve:
            compression: gzip
            creds_file_path: '/etc/bindplane-agent/ingestion-auth.json'
            customer_id: '<customer_id>'
            endpoint: malachiteingestion-pa.googleapis.com
            log_type: HP_PROCURVE
            raw_log_field: body
    
    service:
        pipelines:
            logs/hp_procurve_to_chronicle:
                receivers:
                    - udplog
                exporters:
                    - chronicle/hp_procurve
    

Configuration parameters

Replace the following placeholders:

  • Receiver configuration:

    • listen_address: IP address and port to listen on:
      • 0.0.0.0 to listen on all interfaces (recommended)
      • Port 514 is the standard syslog port (requires root on Linux; use 1514 for non-root)
  • Exporter configuration:

    • creds_file_path: Full path to ingestion authentication file:
      • Linux: /etc/bindplane-agent/ingestion-auth.json
      • Windows: C:\Program Files\observIQ OpenTelemetry Collector\ingestion-auth.json
    • customer_id: Customer ID copied from the Google SecOps console
    • endpoint: Regional endpoint URL:
      • US: malachiteingestion-pa.googleapis.com
      • Europe: europe-malachiteingestion-pa.googleapis.com
      • Asia: asia-southeast1-malachiteingestion-pa.googleapis.com
      • See Regional Endpoints for complete list

Save the configuration file

  • After editing, save the file:
    • Linux: Press Ctrl+O, then Enter, then Ctrl+X
    • Windows: Click File > Save

Restart the Bindplane agent to apply the changes

  • To restart the Bindplane agent in Linux, run the following command:

    sudo systemctl restart observiq-otel-collector
    
    1. Verify the service is running:

      sudo systemctl status observiq-otel-collector
      
    2. Check logs for errors:

      sudo journalctl -u observiq-otel-collector -f
      
  • To restart the Bindplane agent in Windows, choose one of the following options:

    • Command Prompt or PowerShell as administrator:

      net stop observiq-otel-collector && net start observiq-otel-collector
      
    • Services console:

      1. Press Win+R, type services.msc, and press Enter.
      2. Locate observIQ OpenTelemetry Collector.
      3. Right-click and select Restart.
      4. Verify the service is running:

        sc query observiq-otel-collector
        
      5. Check logs for errors:

        type "C:\Program Files\observIQ OpenTelemetry Collector\log\collector.log"
        

Configure syslog on HP ProCurve switch

  1. Sign in to the HP ProCurve switch with SSH.
  2. Verify the switch interface by using the following command:

    show ip int br
    
  3. Enable config mode on the switch using the following command:

    console# conf t
    
  4. Configure the switch to send logs using the following commands:

    logging host <bindplane-server-ip> transport <udp/tcp> port <port-number>
    logging facility syslog
    logging trap informational
    logging buffer 65536
    logging origin-id hostname
    logging source-interface <interface>
    
    • Replace <bindplane-server-ip> with the Bindplane agent IP address.
    • Replace <port-number> with the configured port (default: 514).
    • Replace <interface> with the source interface for syslog traffic.

UDM mapping table

Log field UDM mapping Logic
AAAScheme read_only_udm.security_result.detection_fields.value Value extracted from descrip field if the key is AAAScheme
AAAType read_only_udm.security_result.detection_fields.value Value extracted from descrip field if the key is AAAType
Chassis ID read_only_udm.security_result.detection_fields.value Value extracted from description field if the key is Chassis ID
Command is read_only_udm.security_result.detection_fields.value Text after Command is in the commandInfo field
CommandSource read_only_udm.security_result.detection_fields.value Value extracted from descrip field if the key is CommandSource
Config-Method read_only_udm.additional.fields.value.string_value If the field exists in the log, it's placed in the additional fields as config_method
ConfigDestination read_only_udm.security_result.detection_fields.value Value extracted from descrip field if the key is ConfigDestination
ConfigSource read_only_udm.security_result.detection_fields.value Value extracted from descrip field if the key is ConfigSource
Device-Name read_only_udm.principal.hostname If the field exists in the log, it's mapped to principal hostname and asset hostname
Event-ID read_only_udm.additional.fields.value.string_value If the field exists in the log, it's placed in the additional fields as event_id
EventIndex read_only_udm.security_result.detection_fields.value Value extracted from descrip field if the key is EventIndex
IfIndex read_only_udm.security_result.detection_fields.value Value extracted from description field if the key is IfIndex
IP: %{IP:IPAddr} read_only_udm.target.ip, read_only_udm.target.asset.ip IP address extracted from the desc field and mapped to target IP and target asset IP
IPAddr read_only_udm.target.ip, read_only_udm.target.asset.ip If the field exists in the log, it's mapped to target IP and target asset IP
Notice-Type read_only_udm.additional.fields.value.string_value If the field exists in the log, it's placed in the additional fields as notice_type
Port ID read_only_udm.security_result.detection_fields.value Value extracted from description field if the key is Port ID
Remote-IP-Address read_only_udm.additional.fields.value.string_value If the field exists in the log, it's placed in the additional fields as remote_ip_address
Service read_only_udm.security_result.detection_fields.value Value extracted from descrip field if the key is Service
Task read_only_udm.security_result.detection_fields.value Value extracted from descrip field if the key is Task
User read_only_udm.principal.user.userid If the field exists in the log, it's mapped to principal user ID
User-Name read_only_udm.principal.user.userid If the field exists in the log, it's mapped to principal user ID
UserName read_only_udm.principal.user.userid If the field exists in the log, it's mapped to principal user ID
UserService read_only_udm.security_result.detection_fields.value Value extracted from desc field if the key is UserService
collection_time.seconds read_only_udm.metadata.event_timestamp.seconds Seconds part of the event timestamp
data This field contains the raw log message and is parsed to extract other fields. It's not mapped to the UDM.
desc read_only_udm.security_result.description Description extracted from the log message
descrip Description extracted from the desc field, further parsed for key-value pairs. It's not mapped to the UDM.
description read_only_udm.security_result.description If the field exists in the log, it's mapped to the security result description
descript read_only_udm.metadata.description If the field exists in the log, it's mapped to the metadata description
event_id read_only_udm.additional.fields.value.string_value If the field exists in the log, it's placed in the additional fields as event_id
eventId read_only_udm.metadata.product_event_type Event ID extracted from the log message
hostname read_only_udm.principal.hostname, read_only_udm.principal.asset.hostname Hostname extracted from the log message and mapped to principal hostname and asset hostname
inter_ip read_only_udm.additional.fields.value.string_value, read_only_udm.intermediary.ip If the field exists in the log and is a valid IP, it's mapped to intermediary IP. Otherwise, it's placed in the additional fields as inter_ip
notice_type read_only_udm.additional.fields.value.string_value If the field exists in the log, it's placed in the additional fields as notice_type
pid read_only_udm.principal.process.pid If the field exists in the log, it's mapped to principal process PID
program Program information extracted from the log message, further parsed to extract module, severity, and action. It's not mapped to the UDM.
proto read_only_udm.network.application_protocol, read_only_udm.additional.fields.value.string_value Protocol extracted from the log message. If it matches known protocols, it's mapped to application protocol. Otherwise, it's placed in the additional fields as Application Protocol
remote_ip_address read_only_udm.principal.ip, read_only_udm.principal.asset.ip, read_only_udm.additional.fields.value.string_value If the field exists in the log and is a valid IP, it's mapped to principal IP and principal asset IP. Otherwise, it's placed in the additional fields as remote_ip_address
severity read_only_udm.security_result.severity, read_only_udm.security_result.severity_details Severity extracted from the program field after splitting by /. It's mapped to UDM severity levels and also stored as raw severity details
src_ip read_only_udm.principal.ip, read_only_udm.principal.asset.ip Source IP extracted from the log message and mapped to principal IP and principal asset IP
status read_only_udm.additional.fields.value.string_value If the field exists in the log, it's placed in the additional fields as status
targetHostname read_only_udm.target.hostname, read_only_udm.target.asset.ip If the field exists in the log, it's mapped to target hostname and target asset IP
target_ip read_only_udm.target.ip, read_only_udm.target.asset.ip Target IP extracted from the log message and mapped to target IP and target asset IP
timestamp read_only_udm.metadata.event_timestamp.seconds Timestamp extracted from the log message and converted to event timestamp
timestamp.seconds read_only_udm.metadata.event_timestamp.seconds Seconds part of the event timestamp
username read_only_udm.principal.user.userid If the field exists in the log, it's mapped to principal user ID
read_only_udm.metadata.event_type Determined based on a combination of fields and logic:
- NETWORK_CONNECTION: if has_principal and has_target are true.
- USER_LOGOUT: if action is WEBOPT_LOGOUT, LOGOUT, or SHELL_LOGOUT.
- USER_LOGIN: if action is LOGIN or WEBOPT_LOGIN_SUC.
- STATUS_UPDATE: if action is not empty or src_ip/hostname are not empty.
- USER_UNCATEGORIZED: if has_user is true.
- GENERIC_EVENT: if none of the these conditions are met.
read_only_udm.metadata.product_name Hardcoded to Procurve
read_only_udm.metadata.vendor_name Hardcoded to HP
read_only_udm.extensions.auth.type Set to MACHINE if event_type is USER_LOGOUT or USER_LOGIN

Need more help? Get answers from Community members and Google SecOps professionals.