Capacity buffers help you reduce Pod startup latency for your Google Kubernetes Engine (GKE) workloads by letting you proactively declare tiers of active or standby capacity buffers in your cluster. By declaring spare capacity ahead of time, you can achieve faster workload startups in a cost-efficient manner.
This document explains how capacity buffers work. To learn how to enable and use capacity buffers, see Configure capacity buffers.
When to use capacity buffers
Use capacity buffers for applications that are sensitive to startup latency and need to scale rapidly. When you experience sudden increases in traffic, an active buffer provides pre-provisioned capacity that's designed for low-latency scaling. When you experience a sustained increase in traffic, a standby buffer provides Pod scheduling at a more affordable cost than pre-provisioning.
Capacity buffers provide the following benefits:
- Minimize scaling latency: active buffers provide running nodes, which help minimize latency. Standby buffers resume quickly, providing faster capacity availability than fresh nodes at a lower cost compared to active buffers.
- Cost-efficient over-provisioning: capacity buffers help you maintain a safety net. For large-scale workloads, this approach is often more cost-efficient than other over-provisioning methods, such as lowering horizontal Pod autoscaler (HPA) utilization targets, which can increase idle capacity linearly as your cluster grows.
- Meet workload requirements: you have full control over your capacity buffer configuration. Your options include incorporating custom daemonsets to preload images, tuning startup time, and controlling buffer sizes to fit your needs.
We recommend capacity buffers for latency-sensitive workloads that require rapid scale-up, such as AI agents, AI inference, retail applications during sales events, or game servers during peak player activity.
How capacity buffers work
Implement a capacity buffer by using a Kubernetes CapacityBuffer custom resource to define a buffer of spare capacity. The GKE cluster autoscaler monitors CapacityBuffer resources and treats them as pending demand to help ensure that spare capacity is available. If your cluster doesn't have enough capacity to satisfy the resource requests defined in the buffer, the cluster autoscaler provisions additional nodes.
When a workload scales up, GKE schedules pending Pods on available capacity in the following priority order:
- Running nodes in an active buffer
- Running nodes in a standby buffer that haven't been suspended yet
- Suspended nodes in a standby buffer
- Newly provisioned nodes
To schedule pending Pods as quickly as possible, GKE uses available buffer capacity before provisioning new nodes. This priority applies even if a higher-priority rule in a custom ComputeClass would otherwise provision a new node.
Buffer capacity isn't restricted to the workload referenced in the
scalableRef field. Any pending Pod whose scheduling constraints, such as
node selectors, tolerations, and resource requests, match the buffer node's
configuration can claim that capacity. To reserve a capacity buffer for a
specific workload, configure workload separation by adding matching
tolerations and node selectors (or node affinities) to both the workload and the
capacity buffer.
When a workload consumes capacity from an active buffer, the cluster autoscaler replenishes the active buffer by resuming a node from a compatible standby buffer if one exists, or by provisioning a new node. When a workload or an active buffer consumes a node from a standby buffer, the cluster autoscaler replenishes the standby buffer by provisioning and suspending a new node. When your workload scales back down and nodes become underutilized, the cluster autoscaler deletes the excess running nodes after the scale-down stabilization window rather than resuspending them into the standby buffer. To replenish the standby buffer, GKE provisions and suspends fresh nodes separately.
Capacity buffer strategies
You can configure capacity buffers by using different provisioning strategies based on your requirements for latency and cost.
Active buffer
An active buffer provides running nodes for low-latency scaling of workloads that fit within the reserved capacity. Because the nodes are already running, they provide minimal latency for claiming Pods during a scale-up event.
Standby buffer
A standby buffer provides suspended nodes. The standby strategy is more cost-effective than the active strategy, but introduces a short delay to resume the node before it accepts workloads.
Cost and pricing
Capacity buffers are provided at no extra charge in addition to your standard node-based compute costs, which apply to Standard node pools and Autopilot workloads that select specific hardware. Capacity buffers don't support the Pod-based billing model.
Billing for the underlying nodes differs depending on the buffer type:
- Active buffers: you are charged standard node-based compute rates for the running VMs that GKE maintains to serve as active buffer capacity.
- Standby buffers: while VM instances are suspended, you don't pay compute costs (CPU or memory). You incur minor storage charges (for example, VM boot disks and stored memory state) and costs for associated resources such as static external IP addresses. When GKE resumes the standby VMs to host workloads, standard node-based compute rates apply. For more information, see Suspended instance pricing.
CapacityBuffer CRD
To configure a capacity buffer, you create a CapacityBuffer CustomResourceDefinition (CRD). You can configure the capacity buffer to meet different criteria:
- Fixed replicas: specify a fixed number of buffer Pods to create based on the resource requests of a referenced Pod template. This configuration is the simplest way to create a buffer of a known size.
- Resource limits: specify the total amount of CPU and memory that the buffer should reserve. The controller calculates how many buffer Pods to create based on the resource requests of a referenced Pod template.
- Percentage-based: define the buffer size as a percentage of an existing scalable object that defines a scale subresource (such as a Deployment, StatefulSet, ReplicaSet, or Job). The buffer size adjusts dynamically as the reference workload scales. Percentage-based capacity buffers are only supported for objects that implement the Kubernetes scale subresource.
You can combine these options, for example by setting both replicas and
percentage so that GKE uses the larger value as a minimum
floor, and by setting limits as an upper bound.
For more information, see the CapacityBuffer CRD reference documentation.
Best practices
To optimize for cost-efficiency and responsiveness when configuring capacity buffers, use the following recommendations:
- Use a cost-optimal, standby-first strategy: prioritize standby buffers if your workloads can tolerate a brief scale-up delay of approximately 30 seconds. This strategy avoids cold node boots of fresh VMs without having to incur the full cost of active VMs.
- Use active buffers for latency-sensitive workloads: use active buffers for workloads that can't tolerate node resume times when Pod scheduling time must be as low as possible.
- Use a hybrid strategy to balance performance and cost: Combine a small active buffer with a larger standby buffer for a cost-effective setup. GKE prioritizes refilling the active buffer by resuming nodes from the standby buffer (taking about 30 seconds), while new nodes are provisioned in the background to backfill the standby buffer. This setup absorbs initial spikes with active capacity, and accommodates sustained growth using the lower cost standby capacity.
- Size active buffers for initial bursts: define the size of your active buffer to cover the initial sudden replica spikes you expect to encounter, before standby buffer nodes can resume.
- Size standby buffers for sustained load: define standby buffers that are sufficient to cover the extended load you expect to encounter, so that buffers can refill in the background from a cold start. A sufficiently-sized standby buffer can drop your maximum Pod scheduling latency to the time it takes to resume a node, which is approximately 30 seconds. When the capacity buffer starts to be used and gets refilled, new buffer nodes transition to an active state prior to suspending. This strategy helps to boost active capacity during a prolonged load.
- Use the buffer simulator: experiment with different active and standby buffer sizes to get the best result for your specific workload. Run simulations of workload scaling behavior by using the open-source GKE buffers simulator at https://github.com/gke-labs/buffers-simulator to fine-tune your buffer sizing rules and achieve your performance targets.
- Reduce cold-start latency when scaling workloads from zero: pair workloads that
scale to and from zero using HPA (
minReplicas: 0) with capacity buffers. When demand increases and the workload scales up from zero, GKE immediately schedules Pods on pre-warmed buffer nodes instead of waiting for new compute nodes to provision. - Consider the
optimize-utilizationautoscaling profile on Standard clusters: because capacity buffers already maintain spare headroom, you can configure theoptimize-utilizationautoscaling profile (--autoscaling-profile=optimize-utilization) so that the cluster autoscaler scales down underutilized nodes more quickly after demand drops. This profile also packs Pods more tightly onto nodes, so evaluate whether tighter bin packing fits your workload availability requirements before enabling it.
Calculate your buffer size
When you combine an active buffer with a standby buffer, you can estimate the number of buffer replicas, or simulated buffer Pods, needed to absorb a traffic spike. Calculate this estimate by using your expected scale-up rate in Pods per second, your standby node resume latency, and your cold node creation latency. These latencies vary by VM machine series and node configuration. For example, standby node resume latency is typically 30 to 35 seconds, and new node creation latency is typically 60 to 120 seconds depending on the machine series. To measure actual latencies for your cluster, see Monitor startup latency metrics.
Calculate your active buffer size to cover the Pods created while standby nodes resume:
\[ \text{Active buffer replicas} = \text{Expected scale-up rate} \times \text{Standby node resume latency} \]
Calculate your standby buffer size to cover the remaining Pods created while new cold nodes finish provisioning:
\[ \text{Standby buffer replicas} = (\text{Expected scale-up rate} \times \text{Cold node creation latency}) - \text{Active buffer replicas} \]
For example, if your workload scales up at 2 Pods per second, standby nodes take 30 seconds to resume, and new cold nodes take 90 seconds to provision:
- Your active buffer needs \( 2 \times 30 = 60 \) replicas to absorb the first 30 seconds of the spike.
- Your standby buffer needs \( (2 \times 90) - 60 = 120 \) replicas to cover the remaining 60 seconds while the cluster autoscaler provisions new cold nodes in the background to replenish your buffers. If the spike continues past 90 seconds at the same rate, those replenished nodes are ready to serve incoming Pods without wait time.
To test these estimates against your workload scaling patterns, run simulations with the GKE buffers simulator.
Requirements and limitations
Capacity buffers have the following requirements and limitations:
- Capacity buffers are available for GKE clusters running version 1.35.2-gke.1842000 or later for active buffers, and version 1.36.0-gke.2253000 for standby buffers.
- Capacity buffers support only workloads that use a node-based billing model for Standard node pools and Autopilot node pools that select specific hardware. Capacity buffers don't support workloads that use the Pod-based billing model.
- On Standard clusters, we recommend that you enable node auto-provisioning. Node auto-provisioning allows the cluster autoscaler to create new node pools based on the resource requests in your CapacityBuffer. If you don't enable node auto-provisioning, the cluster autoscaler only scales up existing node pools.
- Active and standby capacity buffers consume quotas differently:
- Running nodes in an active buffer count against your vCPU, memory, disk, and IP address Compute Engine quotas.
- Suspended nodes in a standby buffer don't count against
Compute Engine vCPU or memory quotas while suspended. However,
they continue to consume IP address quotas and disk quotas,
including the
Persistent disk standard (GB)quota used to store the suspended VM's memory. - In Kubernetes, both active and suspended standby buffer units count toward Kubernetes resource quotas in your namespace as if the buffer Pods were running.
- If your CapacityBuffer configuration dependency (for example, a PodTemplate) selects a custom ComputeClass, the dependency must define any tolerations, node selectors, or runtime classes required to schedule on the provisioned nodes (for example, requirements for GKE Sandbox). For instructions, see custom ComputeClass documentation.
Standby buffers have the following additional limitations:
- They are supported on Standard clusters with node auto-provisioning enabled.
- They are supported on Autopilot clusters running version 1.36.0-gke.2853000 or later.
- Nodes with attached GPUs or TPUs are not supported.
- Local SSDs are not supported.
- Although standby buffers support customer-managed encryption keys (CMEK) for the node's storage, the node's memory is encrypted using Google-owned and Google-managed encryption keys during suspension.
- Confidential Google Kubernetes Engine Nodes are not supported.
- Standby buffers support only GKE Container-Optimized OS and Ubuntu node images. Windows Server nodes aren't supported. If you use a custom node operating system, you must ensure that the OS supports Compute Engine suspend and resume operations.
- You should be familiar with limitations related to Compute Engine suspend and resume operations.
Some key limitations include the following:
- Nodes with customer-supplied encryption keys (CSEK)-protected disks are not supported.
- Nodes with more than 208 GB of memory are not supported.
- Bare metal instances are not supported.
- The node OS must support ACPI S3 sleep signals.
- The suspension process length is proportional to the memory size.
What's next