> [!NOTE]
> **Note:** You can only initiate a manual failover using the gcloud CLI tool.

This page describes how to initiate a **manual failover** for a standard tier Memorystore for Redis instance. The manual failover feature allows you to test how normal failovers affect your application.

For an overview of this feature, see [Manual failover](https://docs.cloud.google.com/memorystore/docs/redis/manual-failover-overview).

## Initiating a failover

> [!WARNING]
> **Warning:** Using the `--data-protection-mode=force-data-loss` mode may cause significant data loss. See [Manual failover](https://docs.cloud.google.com/memorystore/docs/redis/manual-failover-overview) to learn the appropriate scenarios for using the `force-data-loss` mode.

1. Open a terminal window

2. Use the `gcloud config` command to set your default project:


   ```
   gcloud config set core/project PROJECT_ID
   ```

   <br />

3. Use the following command to initiate a failover:


   ```
   gcloud redis instances failover INSTANCE_NAME
   ```

   <br />

## Optional data protection mode

The two available data protection modes are:

- `limited-data-loss` mode (default).
- `force-data-loss` mode.

To set the data protection mode, use one of the following commands:

    gcloud redis instances failover INSTANCE_NAME --data-protection-mode=limited-data-loss

or

    gcloud redis instances failover INSTANCE_NAME --data-protection-mode=force-data-loss

## How data protection modes work

The `limited-data-loss` mode minimizes data loss by verifying that the
difference in data between the primary and replica is below 30 MB before
initiating the failover. The offset on the primary is incremented for each byte
of data that must be synchronized to its replicas. In the `limited-data-loss`
mode, the failover will abort if the greatest offset delta between the primary
and each replica is 30MB or greater. If you can tolerate more data loss and want
to aggressively execute the failover, try setting the data protection mode to
`force-data-loss`.

The `force-data-loss` mode employs a chain of failover strategies to
aggressively execute the failover. It does not check the offset delta between
the primary and replicas before initiating the failover; you can potentially
lose more than 30MB of data changes.

See [Manual failover](https://docs.cloud.google.com/memorystore/docs/redis/manual-failover-overview)
for additional information.