This document provides instructions on how to create or update a VLAN
attachment in Google Distributed Cloud (GDC) air-gapped.

A VLAN attachment represents an attachment of a Virtual Local Area Network
(VLAN) and its associated Border Gateway Protocol (BGP) session configuration to
an interconnect link. The VLAN specifies which part of your network has access
through this connection.

The VLAN attachment and its associated BGP session configuration are a required
resource for setting up a secure air-gapped connection with high bandwidth and
low latency.

This document is for developers within the application operator group who are
looking to establish connectivity with interconnects. For more information, see
[Audiences for GDC air-gapped
documentation](https://docs.cloud.google.com/distributed-cloud/hosted/docs/latest/gdcag/resources/audiences).

## Before you begin

To create or update a VLAN attachment, you must have the following:

- A submitted ticket in the GDC portal requesting an interconnect with your chosen specifications, such as 10 G of redundant connectivity.
- The necessary resource information and IDs for the interconnect resources that the Infrastructure Operator (IO) configures. For more information, see [Interconnect creation
  process](https://docs.cloud.google.com/distributed-cloud/hosted/docs/latest/gdcag/platform/pa-user/interconnects/interconnect-overview#interconnect-creation).
- The necessary identity and access roles. For more information, see [Prepare predefined roles and permissions](https://docs.cloud.google.com/distributed-cloud/hosted/docs/latest/gdcag/platform/pa-user/interconnects/interconnect-overview.md.txt#prepare-roles).

## Create or update a VLAN attachment

To create or update a VLAN attachment, follow these steps:

1. Create a YAML file named `interconnectattachment.yaml`.
2. Add the following content to the file:

   ```yaml
   apiVersion: system.private.gdc.goog/v1alpha1
   kind: InterconnectAttachment
   metadata:
     name: UNIQUE_INTERCONNECT_NAME
     namespace: gpc-system
   spec:
     interconnectLinkRef:
       name: INTERCONNECT_LINK_NAME
       namespace: gpc-system
     parentInterconnectRef:
       name: INTERCONNECT_GROUP_NAME
       namespace: gpc-system
     parentInterconnectType: DirectConnect
     bgpSessionConfig:
       localIP: LOCAL_IP_SUBNET
       localASN: LOCAL_ASN
       peerASN: PEER_ASN
       peerIP: PEER_IP
     peerExternalSubnets:
       - PEER_EXTERNAL_SUBNET
     routePolicyRef:
       name: ROUTE_POLICY_NAME
       namespace: gpc-system
     attachmentGroup:
       name: ATTACHMENT_GROUP_NAME
       namespace: gpc-system
     vlanID: VLAN_ID
   status: {}

   ```
3. Replace the following:

   - `UNIQUE_INTERCONNECT_NAME`: unique name for this `InterconnectAttachment` resource.
   - `INTERCONNECT_LINK_NAME`: the universal object reference to the interconnect link in the `gpc-system` namespace.
   - `INTERCONNECT_GROUP_NAME`: the universal object reference to the interconnect group in the `gpc-system` namespace containing `INTERCONNECT_LINK_NAME`.
   - `LOCAL_IP_SUBNET`: the local IP address of the `/31` peer on the GDC side.
   - `LOCAL_ASN`: the local autonomous system number (ASN) for BGP.
   - `PEER_ASN`: the peer autonomous system number (ASN) for BGP.
   - `PEER_IP`: the peer IP address of the `/31` peer on the side of the peer.
   - `PEER_EXTERNAL_SUBNET`: the peer external subnet that this interconnect allows. If there is more than one subnet, list all of them in the `peerExternalSubnets` field.
   - `ROUTE_POLICY_NAME`: the universal object reference to the route policy in the `gpc-system` namespace.
   - `ATTACHMENT_GROUP_NAME`: the universal object reference to the attachment group in the `gpc-system` namespace that this attachment is a part of.
   - `VLAN_ID`: the VLAN ID to use on this interconnect.

   Keep `parentInterconnectType` set to `DirectConnect`. VLAN attachments
   that you create in your organization must use this type. The
   `CustomerPeering` type is on the deprecation path. For more
   information, see
   [Interconnect types](https://docs.cloud.google.com/distributed-cloud/hosted/docs/latest/gdcag/platform/pa-user/interconnects/interconnect-overview.md.txt#interconnect-types).
4. Create the VLAN attachment:

   ```bash
   kubectl apply -f interconnectattachment.yaml -n gpc-system
   --kubeconfig=MANAGEMENT_API_SERVER
   ```

   Replace `MANAGEMENT_API_SERVER` with the path to the
   kubeconfig file for the Management API server.
5. Check that the creation of the VLAN attachment is successful:

   ```bash
   kubectl get interconnectattachment -n gpc-system
   --kubeconfig=MANAGEMENT_API_SERVER
   ```
6. The output returns the VLAN attachment and shows `True` in the `Ready` column:

       NAME                                                   AGE    TYPE            MTU   VLAN-ID   INTERCONNECT GROUP                   INTERCONNECT LINK                           READY
       interconnect-attachment-zv-aa-blsw01-directconnect-1   3d2h   DirectConnect         3966      interconnect-group-directconnect-1   interconnect-zv-aa-blsw01-directconnect-1   True

## What's next