This page describes the specialized Network Function Kubernetes operator that
Google Distributed Cloud connected ships with. This operator implements a set of
CustomResourceDefinitions (CRDs) that allow Distributed Cloud connected
to execute high-performance workloads.

Network Function operator and SR-IOV functionality is not available on
Distributed Cloud connected servers.

The Network Function operator lets you do the following:

- Poll for existing network devices on a node.
- Query the IP address and physical link state for each network device on a node.
- Provision additional network interfaces on a node.
- Configure low-level system features on the node's physical machine required to support high-performance workloads.
- Use single-root input/output virtualization (SR-IOV) on PCI Express network interfaces to virtualize them into multiple virtual interfaces. You can then configure your Distributed Cloud connected workloads to use those virtual network interfaces.

Distributed Cloud connected support for SR-IOV is based on the
following open source projects:

- [Kubernetes SR-IOV Network Operator](https://github.com/k8snetworkplumbingwg/sriov-network-operator)
- [Multus-CNI plugin](https://github.com/k8snetworkplumbingwg/multus-cni)
- [SRIOV-CNI plugin](https://github.com/k8snetworkplumbingwg/sriov-cni)

## Prerequisites

The Network Function operator fetches network configuration from the Distributed Cloud Edge Network API.
To allow this, you must grant the Network Function operator service account the Edge Network Viewer role
(`roles/edgenetwork.viewer`) using the following command:

```
gcloud projects add-iam-policy-binding PROJECT_ID \
  --role roles/edgenetwork.viewer \
  --member "serviceAccount:PROJECT_ID.svc.id.goog[nf-operator/nf-angautomator-sa]"
```

Replace `PROJECT_ID` with the ID of the target Google Cloud project.

## Network Function operator resources

The Distributed Cloud connected Network Function operator implements
the following Kubernetes CRDs:

- [`Network`](https://docs.cloud.google.com/distributed-cloud/connected/1.6.1/docs/network-function#Network). Defines a virtual network that Pods can use to communicate with internal and external resources. You must create the corresponding VLAN using the Distributed Cloud Edge Network API before specifying it in this resource. For instructions, see [Create a network](https://docs.cloud.google.com/distributed-cloud/connected/1.6.1/docs/networking#create_a_network).
- [`NetworkInterfaceState`](https://docs.cloud.google.com/distributed-cloud/connected/1.6.1/docs/network-function#NetworkInterfaceState). Enables the discovery of network interface states and querying a network interface for link state and IP address.
- [`NodeSystemConfigUpdate`](https://docs.cloud.google.com/distributed-cloud/connected/1.6.1/docs/network-function#NodeSystemConfigUpdate). Enables the configuration of low-level system features such as kernel options and `Kubelet` flags.
- [`SriovNetworkNodePolicy`](https://docs.cloud.google.com/distributed-cloud/connected/1.6.1/docs/network-function#SriovNetworkNodePolicy). Selects a group of SR-IOV virtualized network interfaces and instantiates the group as a Kubernetes resource. You can use this resource in a `NetworkAttachmentDefinition` resource.
- [`SriovNetworkNodeState`](https://docs.cloud.google.com/distributed-cloud/connected/1.6.1/docs/network-function#SriovNetworkNodeState). Lets you query the provisioning state of the `SriovNetworkNodePolicy` resource on a Distributed Cloud node.
- [`NetworkAttachmentDefinition`](https://docs.cloud.google.com/distributed-cloud/connected/1.6.1/docs/network-function#NetworkAttachmentDefinition). Lets you attach Distributed Cloud Pods to one or more logical or physical networks on your Distributed Cloud connected node. You must create the corresponding VLAN using the Distributed Cloud Edge Network API before specifying it in this resource. For instructions, see [Create a network](https://docs.cloud.google.com/distributed-cloud/connected/1.6.1/docs/networking#create_a_network).

The Network Function operator also lets you define secondary network
interfaces that do not use SR-IOV virtual functions.

### `Network` resource

> [!WARNING]
>
> **Preview**
>
>
> This feature is
>
> subject to the "Pre-GA Offerings Terms" in the General Service Terms section of the
> [Service Specific
> Terms](https://docs.cloud.google.com/terms/service-terms#1).
>
> Pre-GA features are available "as is" and might have limited support.
>
> For more information, see the
> [launch stage descriptions](https://cloud.google.com/products/#product-launch-stages).

The `Network` resource defines a virtual network within the
Distributed Cloud connected rack that Pods within your
Distributed Cloud connected cluster can use to communicate with
internal and external resources.

The `Network` resource provides the following configurable parameters for the
network interface exposed as writable fields:

- `spec.type`: specifies the network transport layer for this network. The only valid value is `L2`. You must also specify a `nodeInterfaceMatcher.interfaceName` value.
- `spec.nodeInterfaceMatcher.interfaceName`: the name of the physical network interface on the target Distributed Cloud connected node to use with this network.
- `spec.gateway4`: the IP address of the network gateway for this network.
- `spec.l2NetworkConfig.prefixLength4`: specifies the CIDR range for this network.

The following example illustrates the structure of the resource:

    apiVersion: networking.gke.io/v1
    kind: Network
    metadata:
      name: vlan200-network
      annotations:
        networking.gke.io/gdce-vlan-id: 200
        networking.gke.io/gdce-vlan-mtu: 1500
    spec:
      type: L2
      nodeInterfaceMatcher:
        interfaceName: gdcenet0.200
      gateway4: 10.53.0.1

### `NetworkInterfaceState` resource

The `NetworkInterfaceState` resource is a read-only resource that lets you
discover physical network interfaces on the node and collect runtime statistics
on the network traffic flowing through those interfaces.
Distributed Cloud creates a `NetworkInterfaceState` resource
for each node in a cluster.

The default configuration of Distributed Cloud connected machines
includes a bonded network interface on the Rack Select Network Daughter Card
(rNDC) named `gdcenet0`. This interface bonds the `eno1np0` and `eno2np1`
network interfaces. Each of those is connected to one
Distributed Cloud ToR switch, respectively.

The `NetworkInterfaceState` resource provides the following categories of
network interface information exposed as read-only status fields.

General information:

- `status.interfaces.ifname`: the name of the target network interface.
- `status.lastReportTime`: the time and date of the last status report for the target interface.

IP address configuration information:

- `status.interfaces.interfaceinfo.address`: the IP address assigned to the target interface.
- `status.interfaces.interfaceinfo.dns`: the IP address of the DNS server assigned to the target interface.
- `status.interfaces.interfaceinfo.gateway`: the IP address of the network gateway serving the target interface.
- `status.interfaces.interfaceinfo.prefixlen`: the length of the IP prefix.

Hardware information:

- `status.interfaces.linkinfo.broadcast`: the broadcast MAC address of the target interface.
- `status.interfaces.linkinfo.businfo`: the PCIe device path in `bus:slot.function` format.
- `status.interfaces.linkinfo.flags`: the interface flags---for example, `BROADCAST`.
- `status.interfaces.linkinfo.macAddress`: the Unicast MAC address of the target interface.
- `status.interfaces.linkinfo.mtu`: the MTU value for the target interface.

Reception statistics:

- `status.interfaces.statistics.rx.bytes`: the total bytes received by the target interface.
- `status.interfaces.statistics.rx.dropped`: the total packets dropped by the target interface.
- `status.interfaces.statistics.rx.errors`: the total packet receive errors for the target interface.
- `status.interfaces.statistics.rx.multicast`: the total multicast packets received by the target interface.
- `status.interfaces.statistics.rx.overErrors`: the total packet receive over errors for the target interface.
- `status.interfaces.statistics.rx.packets`: the total packets received by the target interface.

Transmission statistics:

- `status.interfaces.statistics.tx.bytes`: the total bytes transmitted by the target interface.
- `status.interfaces.statistics.tx.carrierErrors`: the total carrier errors encountered by the target interface.
- `status.interfaces.statistics.tx.collisions`: the total packet collisions encountered by the target interface.
- `status.interfaces.statistics.tx.dropped`: the total packets dropped by the target interface.
- `status.interfaces.statistics.tx.errors`: the total transmission errors for the target interface.
- `status.interfaces.statistics.tx.packets`: the total packets transmitted by the target interface.

The following example illustrates the structure of the resource:

    apiVersion: networking.gke.io/v1
    kind: NetworkInterfaceState
    metadata:
      name: MyNode1
    nodeName: MyNode1
    status:
      interfaces:
      - ifname: eno1np0
        linkinfo:
          businfo: 0000:1a:00.0
          flags: up|broadcast|multicast
          macAddress: ba:16:03:9e:9c:87
          mtu: 9000
        statistics:
          rx:
            bytes: 1098522811
            errors: 2
            multicast: 190926
            packets: 4988200
          tx:
            bytes: 62157709961
            packets: 169847139
      - ifname: eno2np1
        linkinfo:
          businfo: 0000:1a:00.1
          flags: up|broadcast|multicast
          macAddress: ba:16:03:9e:9c:87
          mtu: 9000
        statistics:
          rx:
            bytes: 33061895405
            multicast: 110203
            packets: 110447356
          tx:
            bytes: 2370516278
            packets: 11324730
      - ifname: enp95s0f0np0
        interfaceinfo:
        - address: fe80::63f:72ff:fec4:2bf4
          prefixlen: 64
        linkinfo:
          businfo: 0000:5f:00.0
          flags: up|broadcast|multicast
          macAddress: 04:3f:72:c4:2b:f4
          mtu: 9000
        statistics:
          rx:
            bytes: 37858381
            multicast: 205645
            packets: 205645
          tx:
            bytes: 1207334
            packets: 6542
      - ifname: enp95s0f1np1
        interfaceinfo:
        - address: fe80::63f:72ff:fec4:2bf5
          prefixlen: 64
        linkinfo:
          businfo: 0000:5f:00.1
          flags: up|broadcast|multicast
          macAddress: 04:3f:72:c4:2b:f5
          mtu: 9000
        statistics:
          rx:
            bytes: 37852406
            multicast: 205607
            packets: 205607
          tx:
            bytes: 1207872
            packets: 6545
      - ifname: enp134s0f0np0
        interfaceinfo:
        - address: fe80::63f:72ff:fec4:2b6c
          prefixlen: 64
        linkinfo:
          businfo: 0000:86:00.0
          flags: up|broadcast|multicast
          macAddress: 04:3f:72:c4:2b:6c
          mtu: 9000
        statistics:
          rx:
            bytes: 37988773
            multicast: 205584
            packets: 205584
          tx:
            bytes: 1212385
            packets: 6546
      - ifname: enp134s0f1np1
        interfaceinfo:
        - address: fe80::63f:72ff:fec4:2b6d
          prefixlen: 64
        linkinfo:
          businfo: 0000:86:00.1
          flags: up|broadcast|multicast
          macAddress: 04:3f:72:c4:2b:6d
          mtu: 9000
        statistics:
          rx:
            bytes: 37980702
            multicast: 205548
            packets: 205548
          tx:
            bytes: 1212297
            packets: 6548
      - ifname: gdcenet0
        interfaceinfo:
        - address: 208.117.254.36
          prefixlen: 28
        - address: fe80::b816:3ff:fe9e:9c87
          prefixlen: 64
        linkinfo:
          flags: up|broadcast|multicast
          macAddress: ba:16:03:9e:9c:87
          mtu: 9000
        statistics:
          rx:
            bytes: 34160422968
            errors: 2
            multicast: 301129
            packets: 115435591
          tx:
            bytes: 64528301111
            packets: 181171964
         .. <remaining interfaces omitted>
       lastReportTime: "2022-03-30T07:35:44Z"

### `NodeSystemConfigUpdate` resource

The `NodeSystemConfigUpdate` resource lets you make changes to the node's
operating system configuration as well as modify `Kubelet` flags. Changes other
than `sysctl` changes require a node reboot.

When instantiating this resource, you must specify the target nodes in
the `nodeSelector` field. You must include all key-value pairs for each
target node in the `nodeSelector` field. When you specify more than one target
node in this field, the target nodes are updated one node at a time.

CAUTION: The `nodeName` field has been deprecated. Using it immediately reboots
the target nodes, including local control plane nodes, which can halt critical
workloads.

The `NodeSystemConfigUpdate` resource provides the following configuration fields
specific to Distributed Cloud connected:

- `spec.containerRuntimeDNSConfig.ip`: specifies a list of IP addresses for private image registries.
- `spec.containerRuntimeDNSConfig`: specifies a list of custom DNS entries used by the Container Runtime Environment
  on each Distributed Cloud connected node. Each entry consists of the following fields:

  - `ip`: specifies the target IPv4 address,
  - `domain`: specifies the corresponding domain,
  - `interface`: specifies the network egress interface through which the IP address specified in the `ip` field is reachable. You can specify an interface defined through the following resources: `CustomNetworkInterfaceConfig`, `Network` (by annotation), `NetworkAttachmentDefinition`, (by annotation). This is a preview-level feature.
- `spec.kubeletConfig.cpuManagerPolicy`: specifies the Kubernetes CPUManager policy. Valid values are `None` and `Static`.

- `spec.kubeletConfig.topologyManagerPolicy`: specifies the Kubernetes TopologyManager policy. Valid values are `None`, `BestEffort`,
  `Restricted`, and `SingleNumaMode`.

- `spec.osConfig.hugePagesConfig`: specifies the huge page configuration per
  NUMA node. Valid values are `2MB` and `1GB`. The number of huge pages
  requested is evenly distributed across both NUMA nodes in the system. For
  example, if you allocate 16 huge pages at 1 GB each, then each node
  receives a pre-allocation of 8 GB.

- `spec.osConfig.isolatedCpusPerSocket`: specifies the number of isolated CPUs
  per socket. Required if `cpuManagerPolicy` is set to `Static`. The maximum number
  of isolated CPUs must be fewer than 80% of the total CPUs in the node.

- `spec.osConfig.cpuIsolationPolicy`: specifies the CPU isolation policy. The
  `Default` policy only isolates `systemd` tasks from CPUs reserved for
  workloads. The `Kernel` policy marks the CPUs as `isolcpus` and sets the
  `rcu_nocb`, `nohz_full`, and `rcu_nocb_poll` flags on each CPU.

- `spec.sysctls.NodeLevel`: specifies the `sysctls` parameters that you can
  configure globally on a node by using the Network Function operator. The
  configurable parameters are as follows:

  - `fs.inotify.max_user_instances`
  - `fs.inotify.max_user_watches`
  - `kernel.sched_rt_runtime_us`
  - `kernel.core_pattern`
  - `net.ipv4.tcp_wmem`
  - `net.ipv4.tcp_rmem`
  - `net.ipv4.tcp_slow_start_after_idle`
  - `net.ipv4.udp_rmem_min`
  - `net.ipv4.udp_wmem_min`
  - `net.ipv4.tcp_rmem`
  - `net.ipv4.tcp_wmem`
  - `net.core.rmem_max`
  - `net.core.wmem_max`
  - `net.core.rmem_default`
  - `net.core.wmem_default`
  - `net.netfilter.nf_conntrack_tcp_timeout_unacknowledged`
  - `net.netfilter.nf_conntrack_tcp_timeout_max_retrans`
  - `net.sctp.auth_enable`
  - `net.sctp.sctp_mem`
  - `net.ipv4.udp_mem`
  - `net.ipv4.tcp_mem`
  - `net.ipv4.tcp_slow_start_after_idle`
  - `net.sctp.auth_enable`
  - `vm.max_map_count`

  You can also scope both safe and unsafe `sysctls` parameters to a specific
  Pod or namespace by using the
  [`tuning` Container Networking Interface (CNI) plug-in](https://www.cni.dev/plugins/current/meta/tuning/).

The `NodeSystemConfigUpdate` resource provides the following read-only general
status fields:

- `status.lastReportTime`: the most recent time that status was reported for the target interface.
- `status.conditions.lastTransitionTime`: the most recent time that the condition of the interface has changed.
- `status.conditions.observedGeneration`: denotes the `.metadata.generation` value on which the initial condition was based.
- `status.conditions.message`: an informative message describing the change of the interface's condition.
- `status.conditions.reason`: a programmatic identifier denoting the reason for the last change of the interface's condition.
- `status.conditions.status`: the status descriptor of the condition. Valid values are `True`, `False`, and `Unknown`.
- `status.conditions.type`: the condition type in camelCase.

The following example illustrates the structure of the resource:

    apiVersion: networking.gke.io/v1
    kind: NodeSystemConfigUpdate
    metadata:
      name: node-pool-1-config
      namespace: default
    spec:
      nodeSelector:
        baremetal.cluster.gke.io/node-pool: node-pool-1
        networking.gke.io/worker-network-sriov.capable: true
      sysctls:
        nodeLevel:
          "net.ipv4.udp_mem" : "12348035 16464042 24696060"
      kubeletConfig:
        topologyManagerPolicy: BestEffort
        cpuManagerPolicy: Static
      osConfig:
        hugePagesConfig:
          "TWO_MB": 0
          "ONE_GB": 16
        isolatedCpusPerSocket:
          "0": 10
          "1": 10

### `SriovNetworkNodePolicy` resource

The `SriovNetworkNodePolicy` resource lets you allocate a group of SR-IOV
virtual functions (VFs) on a Distributed Cloud connected physical
machine and instantiate that group as a Kubernetes resource. You can then use
this resource in a `NetworkAttachmentDefinition` resource.

You can select each target VF by its PCIe vendor and device ID, its PCIe device
addresses, or by its Linux enumerated device name. The SR-IOV Network Operator
configures each physical network interface to provision the target VFs.
This includes updating the network interface firmware, configuring the Linux
kernel driver, and rebooting the Distributed Cloud connected machine,
if necessary.

To discover the network interfaces available on your node, you can look up the
[`NetworkInterfaceState` resources](https://docs.cloud.google.com/distributed-cloud/connected/1.6.1/docs/network-function#NetworkInterfaceState)
on that node in the `nf-operator` namespace.

The following example illustrates the structure of the resource:

    apiVersion: sriovnetwork.k8s.cni.cncf.io/v1
    kind: SriovNetworkNodePolicy
    metadata:
      name: mlnx6-p2-sriov-en2
      namespace: sriov-network-operator
    spec:
      deviceType: netdevice
      isRdma: true
      mtu: 9000
      nicSelector:
        pfNames:
        - enp134s0f1np1
      nodeSelector:
        edgecontainer.googleapis.com/network-sriov.capable: "true"
      numVfs: 31
      priority: 99
      resourceName: mlnx6_p2_sriov_en2

The preceding example creates a maximum of 31 VFs from the second port on the
network interface named `enp134s0f1np1` with an MTU value of `9000` (the maximum
allowed value). Use the node selector label
`edgecontainer.googleapis.com/network-sriov.capable`, which is present on all
Distributed Cloud connected nodes capable of SR-IOV.

For information about using this resource, see
[`SriovNetworkNodeState`](https://github.com/k8snetworkplumbingwg/sriov-network-operator#sriovnetworknodepolicy).

### `SriovNetworkNodeState` resource

The `SriovNetworkNodeState` read-only resource lets you query the provisioning
state of the `SriovNetworkNodePolicy` resource on a
Distributed Cloud connected node. It returns the complete
configuration of the `SriovNetworkNodePolicy` resource on the node
as well as a list of active VFs on the node. The `status.syncStatus` field
indicates whether all `SriovNetworkNodePolicy` resources defined for the node
have been properly applied.

The following example illustrates the structure of the resource:

    apiVersion: sriovnetwork.k8s.cni.cncf.io/v1
    kind: SriovNetworkNodeState
    metadata:
      name: MyNode1
      namespace: sriov-network-operator
    spec:
      dpConfigVersion: "1969684"
      interfaces:
      - mtu: 9000
        name: enp134s0f1np1
        numVfs: 31
        pciAddress: 0000:86:00.1
        vfGroups:
        - deviceType: netdevice
          mtu: 9000
          policyName: mlnx6-p2-sriov-en2
          resourceName: mlnx6_p2_sriov_en2
          vfRange: 0-30
    status:

    Status:
      Interfaces:
        Device ID:    1015
        Driver:       mlx5_core
        Link Speed:   25000 Mb/s
        Link Type:    ETH
        Mac:          ba:16:03:9e:9c:87
        Mtu:          9000
        Name:         eno1np0
        Pci Address:  0000:1a:00.0
        Vendor:       15b3
        Device ID:    1015
        Driver:       mlx5_core
        Link Speed:   25000 Mb/s
        Link Type:    ETH
        Mac:          ba:16:03:9e:9c:87
        Mtu:          9000
        Name:         eno2np1
        Pci Address:  0000:1a:00.1
        Vendor:       15b3
        Vfs:
      - Vfs:
        - deviceID: 101e
          driver: mlx5_core
          mac: c2:80:29:b5:63:55
          mtu: 9000
          name: enp134s0f1v0
          pciAddress: 0000:86:04.1
          vendor: 15b3
          vfID: 0
        - deviceID: 101e
          driver: mlx5_core
          mac: 7e:36:0c:82:d4:20
          mtu: 9000
          name: enp134s0f1v1
          pciAddress: 0000:86:04.2
          vendor: 15b3
          vfID: 1
          .. <omitted 29 other VFs here>
      syncStatus: Succeeded

For information about using this resource, see
[`SriovNetworkNodeState`](https://github.com/k8snetworkplumbingwg/sriov-network-operator#sriovnetworknodestate).

### `NetworkAttachmentDefinition` resource

The `NetworkAttachmentDefinition` resource lets you attach
Distributed Cloud Pods to one or more logical or physical
networks on your Distributed Cloud connected node. It leverages
the [Multus-CNI](https://github.com/k8snetworkplumbingwg/multus-cni) framework and the
[SRIOV-CNI plugin](https://github.com/k8snetworkplumbingwg/sriov-cni).

Use an annotation to reference the name of the appropriate
`SriovNetworkNodePolicy` resource. When you create this annotation, do the
following:

- Use the key `k8s.v1.cni.cncf.io/resourceName`.
- Use the prefix `gke.io/` in its value, followed by the name of the target `SriovNetworkNodePolicy` resource.

The following example illustrates the structure of the resource:

    apiVersion: "k8s.cni.cncf.io/v1"
    kind: NetworkAttachmentDefinition
    metadata:
      name: sriov-net1
      namespace: mynamespace
      annotations:
        k8s.v1.cni.cncf.io/resourceName: gke.io/mlnx6_p2_sriov_en2

    spec:
      config: '{
      "type": "sriov",
      "cniVersion": "0.3.1",
      "name": "sriov-network",
      "ipam": {
        "type": "host-local",
        "subnet": "10.56.217.0/24",
        "routes": [{
          "dst": "0.0.0.0/0"
        }],
        "gateway": "10.56.217.1"
      }
    }'

## Configure a secondary interface on a Pod using SR-IOV VFs

After you configure a `SriovNetworkNodePolicy` resource and a corresponding
`NetworkAttachmentDefinition` resource, you can configure a secondary network
interface on a Distributed Cloud Pod by using SR-IOV virtual
functions.

To do so, add an annotation to your Distributed Cloud Pod
definition as follows:

- Key: `k8s.v1.cni.cncf.io/networks`
- Value: `nameSpace/<NetworkAttachmentDefinition1,nameSpace/NetworkAttachmentDefinition2...`

The following example illustrates this annotation:

    apiVersion: v1
    kind: Pod
    metadata:
      name: sriovpod
      annotations:
        k8s.v1.cni.cncf.io/networks: mynamespace/sriov-net1
    spec:
      containers:
      - name: sleeppodsriov
        command: ["sh", "-c", "trap : TERM INT; sleep infinity & wait"]
        image: alpine
        securityContext:
          capabilities:
            add:
              - NET_ADMIN

## Configure a secondary interface on a Pod using the MacVLAN driver

> [!WARNING]
>
> **Preview**
>
>
> This feature is
>
> subject to the "Pre-GA Offerings Terms" in the General Service Terms section of the
> [Service Specific
> Terms](https://docs.cloud.google.com/terms/service-terms#1).
>
> Pre-GA features are available "as is" and might have limited support.
>
> For more information, see the
> [launch stage descriptions](https://cloud.google.com/products/#product-launch-stages).

Distributed Cloud connected also supports creating a secondary network
interface on a Pod by using the MacVLAN driver. Only the `gdcenet0` interface
supports this configuration and only on Pods that run containerized workloads.

To configure an interface to use the MacVLAN driver:

1. Configure a `NetworkAttachmentDefinition` resource as shown in the following
   example:

        apiVersion: "k8s.cni.cncf.io/v1"
        kind: NetworkAttachmentDefinition
        metadata:
          name: macvlan-b400-1
          annotations:
            networking.gke.io/gdce-vlan-id: 400
        spec:
          config: '{
          "type": "macvlan",
          "master": "gdcenet0.400",
          "ipam": {
            "type": "static",
            "addresses": [
              {
                "address": "192.168.100.20/27",
                "gateway": "192.168.100.1"
              }
            ]
          ...
          }
        }'

2. Add an annotation to your Distributed Cloud Pod
   definition as follows:

        apiVersion: v1
        kind: Pod
        metadata:
          name: macvlan-testpod1
          annotations:
            k8s.v1.cni.cncf.io/networks: macvlan-b400-1

## Configure a secondary interface on a Pod using Distributed Cloud multi-networking

> [!WARNING]
>
> **Preview**
>
>
> This feature is
>
> subject to the "Pre-GA Offerings Terms" in the General Service Terms section of the
> [Service Specific
> Terms](https://docs.cloud.google.com/terms/service-terms#1).
>
> Pre-GA features are available "as is" and might have limited support.
>
> For more information, see the
> [launch stage descriptions](https://cloud.google.com/products/#product-launch-stages).

Distributed Cloud connected supports creating a secondary network
interface on a Pod by using its multi-network feature. To do so, complete the
following steps:

1. Configure a `Network` resource. For example:

       apiVersion: networking.gke.io/v1
       kind: Network
       metadata:
         name: vlan200-network
       spec:
         type: L2
         nodeInterfaceMatcher:
           interfaceName: vlan200-interface
         gateway4: 10.53.0.1

2. Add an annotation to your Distributed Cloud Pod
   definition as follows:

       apiVersion: v1
       kind: Pod
       metadata:
         name: myPod
         annotations:
           networking.gke.io/interfaces: '[{"interfaceName":"eth1","network":"vlan200-network"}]'
           networking.gke.io/default-interface: eth1
       ...

   ## What's next