## /var/log/audit/ filling up disk space

### Category

OS

### Identified Versions

1.8.0+, 1.9.0+, 1.10.0+, 1.11.0+, 1.12.0+, 1.13.0+

### Symptoms

`/var/log/audit/` is filled with audit logs. You can check the disk
usage by running `sudo du -h -d 1 /var/log/audit`.

### Cause

Since Anthos v1.8, the Ubuntu image is hardened with CIS Level2 Benchmark. And
one of the compliance rules, `4.1.2.2 Ensure audit logs are not automatically deleted`,
ensures the auditd setting `max_log_file_action = keep_logs`. This results in all the
audit rules kept on the disk.

### Workaround

#### Admin workstation

For the admin workstation, you can manually change the auditd settings to rotate the
logs automatically, and then restart the auditd service:

    sed -i 's/max_log_file_action = keep_logs/max_log_file_action = rotate/g' /etc/audit/auditd.conf
    sed -i 's/num_logs = .*/num_logs = 250/g' /etc/audit/auditd.conf
    systemctl restart auditd

The above setting would make auditd automatically rotate its logs once it has
generated more than 250 files (each with 8M size).

#### Cluster nodes

For cluster nodes, apply the following DaemonSet to your cluster to prevent potential issues:

    apiVersion: apps/v1
    kind: DaemonSet
    metadata:
      name: change-auditd-log-action
      namespace: kube-system
    spec:
      selector:
        matchLabels:
          app: change-auditd-log-action
      template:
        metadata:
          labels:
            app: change-auditd-log-action
        spec:
          hostIPC: true
          hostPID: true
          containers:
          - name: update-audit-rule
            image: ubuntu
            command: ["chroot", "/host", "bash", "-c"]
            args:
            - |
              while true; do
                if $(grep -q "max_log_file_action = keep_logs" /etc/audit/auditd.conf); then
                  echo "updating auditd max_log_file_action to rotate with a max of 250 files"
                  sed -i 's/max_log_file_action = keep_logs/max_log_file_action = rotate/g' /etc/audit/auditd.conf
                  sed -i 's/num_logs = .*/num_logs = 250/g' /etc/audit/auditd.conf
                  echo "restarting auditd"
                  systemctl restart auditd
                else
                  echo "auditd setting is expected, skip update"
                fi
                sleep 600
              done
            volumeMounts:
            - name: host
              mountPath: /host
            securityContext:
              privileged: true
          volumes:
          - name: host
            hostPath:
              path: /

Note that making this auditd config change would violate CIS Level2 rule `4.1.2.2 Ensure audit logs are not automatically deleted`.

## systemd-timesyncd not running after reboot on Ubuntu Node

### Category

OS

### Identified Versions

1.7.1-1.7.5, 1.8.0-1.8.4, 1.9.0+

### Symptoms

`systemctl status systemd-timesyncd` should show that the service is dead:

    ● systemd-timesyncd.service - Network Time Synchronization
    Loaded: loaded (/lib/systemd/system/systemd-timesyncd.service; enabled; vendor preset: enabled)
    Active: inactive (dead)

This could cause time out of sync issues.

### Cause

`chrony` was incorrectly installed on Ubuntu OS image, and there's conflict
between `chrony` and `systemd-timesyncd`, where `systemd-timesyncd` would become
inactive and `chrony` become active everytime Ubuntu VM got rebooted. However,
`systemd-timesyncd` should be the default ntp client for the VM.

### Workaround

Option 1: Manually run `restart systemd-timesyncd` every time when VM got rebooted.

Option 2: Deploy the following Daemonset so that `systemd-timesyncd` will always
be restarted if it's dead.

    apiVersion: apps/v1
    kind: DaemonSet
    metadata:
      name: ensure-systemd-timesyncd
    spec:
      selector:
        matchLabels:
          name: ensure-systemd-timesyncd
      template:
        metadata:
          labels:
            name: ensure-systemd-timesyncd
        spec:
          hostIPC: true
          hostPID: true
          containers:
          - name: ensure-systemd-timesyncd
            # Use your preferred image.
            image: ubuntu
            command:
            - /bin/bash
            - -c
            - |
              while true; do
                echo $(date -u)
                echo "Checking systemd-timesyncd status..."
                chroot /host systemctl status systemd-timesyncd
                if (( $? != 0 )) ; then
                  echo "Restarting systemd-timesyncd..."
                  chroot /host systemctl start systemd-timesyncd
                else
                  echo "systemd-timesyncd is running."
                fi;
                sleep 60
              done
            volumeMounts:
            - name: host
              mountPath: /host
            resources:
              requests:
                memory: "10Mi"
                cpu: "10m"
            securityContext:
              privileged: true
          volumes:
          - name: host
            hostPath:
              path: /

## ClientConfig custom resource

`gkectl update` reverts any manual changes that you have made to the ClientConfig
custom resource. We strongly recommend that you back up the ClientConfig
resource after every manual change.

## gkectl check-config validation fails: can't find F5 BIG-IP partitions

Symptoms

:   Validation fails because F5 BIG-IP partitions can't be found, even though they exist.

Potential causes

:   An issue with the F5 BIG-IP API can cause validation to fail.

Resolution

:   Try running `gkectl check-config` again.

## Disruption for workloads with PodDisruptionBudgets

Upgrading clusters can cause disruption or downtime for workloads that use
[PodDisruptionBudgets](https://kubernetes.io/docs/concepts/workloads/pods/disruptions/)
(PDBs).

## Nodes fail to complete their upgrade process

If you have `PodDisruptionBudget` objects configured that are unable to
allow any additional disruptions, node upgrades might fail to upgrade to the
control plane version after repeated attempts. To prevent this failure, we
recommend that you scale up the `Deployment` or `HorizontalPodAutoscaler` to
allow the node to drain while still respecting the `PodDisruptionBudget`
configuration.

To see all `PodDisruptionBudget` objects that do not allow any disruptions:

    kubectl get poddisruptionbudget --all-namespaces -o jsonpath='{range .items[?(@.status.disruptionsAllowed==0)]}{.metadata.name}/{.metadata.namespace}{"\n"}{end}'

## User cluster installation failed because of cert-manager/ca-injector's leader election issue in Anthos 1.9.0

You might see an installation failure due to `cert-manager-cainjector` in crashloop, when the apiserver/etcd is slow. The following command,

```
  kubectl logs --kubeconfig USER_CLUSTER_KUBECONFIG -n kube-system deployments/cert-manager-cainjector
```
might produce something like the following logs:

<br />

    I0923 16:19:27.911174       1 leaderelection.go:278] failed to renew lease kube-system/cert-manager-cainjector-leader-election: timed out waiting for the condition
    E0923 16:19:27.911110       1 leaderelection.go:321] error retrieving resource lock kube-system/cert-manager-cainjector-leader-election-core: Get "https://10.96.0.1:443/api/v1/namespaces/kube-system/configmaps/cert-manager-cainjector-leader-election-core": context deadline exceeded
    I0923 16:19:27.911593       1 leaderelection.go:278] failed to renew lease kube-system/cert-manager-cainjector-leader-election-core: timed out waiting for the condition
    E0923 16:19:27.911629       1 start.go:163] cert-manager/ca-injector "msg"="error running core-only manager" "error"="leader election lost"

Run the following commands to mitigate the problem.

First, scale down the `monitoring-operator` so it will not revert the changes to the
`cert-manager-cainjector` Deployment.

```
kubectl --kubeconfig ADMIN_CLUSTER_KUBECONFIG -n USER_CLUSTER_NAME scale deployment monitoring-operator --replicas=0
```

Second, patch the `cert-manager-cainjector` Deployment to disable leader election, which is safe because we only have one replica running. It is not required for a single replica.

```
# Ensure that we run only 1 cainjector replica, even during rolling updates.
kubectl patch --kubeconfig USER_CLUSTER_KUBECONFIG -n kube-system deployment cert-manager-cainjector --type=strategic --patch '
spec:
  strategy:
    rollingUpdate:
      maxSurge: 0
'
# Add a command line flag for cainjector: `--leader-elect=false`
kubectl patch --kubeconfig USER_CLUSTER_KUBECONFIG -n kube-system deployment cert-manager-cainjector --type=json --patch '[
    {
        "op": "add",
        "path": "/spec/template/spec/containers/0/args/-",
        "value": "--leader-elect=false"
    }
]'
```

Keep `monitoring-operator` replicas at 0 as a mitigation until the installation is finished. Otherwise it will revert the change.

After the installation is finished and the cluster is up and running, turn on the `monitoring-operator` for day-2 operations:

```
kubectl --kubeconfig ADMIN_CLUSTER_KUBECONFIG -n USER_CLUSTER_NAME scale deployment monitoring-operator --replicas=1
```

After upgrading to 1.9.1 or above, these steps will no longer be necessary since Anthos will disable leader-election for cainjector.

## Renewal of certificates might be required before an admin cluster upgrade

Before you begin the admin cluster upgrade process, you should make sure that your admin cluster certificates are currently valid, and renew these certificates if they are not.

> [!NOTE]
> **Note:** If you have begun the upgrade process and discovered an error with certificate expiry, contact Google Support for assistance.

> [!NOTE]
> **Note:** This guidance is strictly for admin cluster certificates renewal.

### Admin cluster certificate renewal process

1. Make sure that OpenSSL is installed on the admin workstation before you begin.

2. Set the `KUBECONFIG` variable:

   ```
   KUBECONFIG=ABSOLUTE_PATH_ADMIN_CLUSTER_KUBECONFIG
   ```

   Replace <var class="edit" translate="no">ABSOLUTE_PATH_ADMIN_CLUSTER_KUBECONFIG</var> with the absolute path to the admin cluster kubeconfig file.
3. Get the IP address and SSH keys for the admin master node:

   ```
   kubectl --kubeconfig "${KUBECONFIG}" get secrets -n kube-system sshkeys \
   -o jsonpath='{.data.vsphere_tmp}' | base64 -d > \
   ~/.ssh/admin-cluster.key && chmod 600 ~/.ssh/admin-cluster.key

   export MASTER_NODE_IP=$(kubectl --kubeconfig "${KUBECONFIG}" get nodes -o \
   jsonpath='{.items[*].status.addresses[?(@.type=="ExternalIP")].address}' \
   --selector='node-role.kubernetes.io/master')
   ```
4. Check if the certificates are expired:

   ```
   ssh -i ~/.ssh/admin-cluster.key ubuntu@"${MASTER_NODE_IP}" \
   "sudo kubeadm alpha certs check-expiration"
   ```

   If the certificates are expired, you must renew them before upgrading the admin cluster.
5. Because the admin cluster kubeconfig file also expires if the admin certificates expire, you should back up this file before expiration.

   - Back up the admin cluster kubeconfig file:

     ```
     ssh -i ~/.ssh/admin-cluster.key ubuntu@"${MASTER_NODE_IP}" 

     "sudo cat /etc/kubernetes/admin.conf" > new_admin.conf
     vi "${KUBECONFIG}"
     ```

     <br />

   - Replace `client-certificate-data` and `client-key-data` in kubeconfig with `client-certificate-data` and `client-key-data` in the `new_admin.conf` file that you created.

6. Back up old certificates:

   This is an optional, but recommended, step.

   ```
   # ssh into admin master if you didn't in the previous step
   ssh -i ~/.ssh/admin-cluster.key ubuntu@"${MASTER_NODE_IP}"

   # on admin master
   sudo tar -czvf backup.tar.gz /etc/kubernetes
   logout

   # on worker node
   sudo scp -i ~/.ssh/admin-cluster.key \
   ubuntu@"${MASTER_NODE_IP}":/home/ubuntu/backup.tar.gz .
   ```
7. Renew the certificates with kubeadm:

   ```
    # ssh into admin master
    ssh -i ~/.ssh/admin-cluster.key ubuntu@"${MASTER_NODE_IP}"
    # on admin master
    sudo kubeadm alpha certs renew all
    
   ```

   <br />

8. Restart static Pods running on the admin master node:

   ```
     # on admin master
     cd /etc/kubernetes
     sudo mkdir tempdir
     sudo mv manifests/*.yaml tempdir/
     sleep 5
     echo "remove pods"
     # ensure kubelet detect those change remove those pods
     # wait until the result of this command is empty
     sudo docker ps | grep kube-apiserver

     # ensure kubelet start those pods again
     echo "start pods again"
     sudo mv tempdir/*.yaml manifests/
     sleep 30
     # ensure kubelet start those pods again
     # should show some results
     sudo docker ps | grep -e kube-apiserver -e kube-controller-manager -e kube-scheduler -e etcd

     # clean up
     sudo rm -rf tempdir

     logout
    
   ```
9. You must validate the renewed certificates, and validate the certificate of kube-apiserver.

   - Check certificates expiration:

     ```
     ssh -i ~/.ssh/admin-cluster.key ubuntu@"${MASTER_NODE_IP}" 

     "sudo kubeadm alpha certs check-expiration"
     ```

     <br />

   - Check certificate of kube-apiserver:

     ```
     # Get the IP address of kube-apiserver
     cat $KUBECONFIG | grep server
     # Get the current kube-apiserver certificate
     openssl s_client -showcerts -connect : 

     | sed -ne '/-BEGIN CERTIFICATE-/,/-END CERTIFICATE-/p'  

     > current-kube-apiserver.crt
     # check expiration date of this cert
     openssl x509 -in current-kube-apiserver.crt -noout -enddate
     ```

     <br />

## Restarting or upgrading vCenter for versions lower than 7.0U2

If the vCenter, for versions lower than 7.0U2, is restarted, after an upgrade or otherwise,
the network name in VM Information from vCenter is incorrect, and results in the machine being in an `Unavailable` state. This eventually leads to the nodes being auto-repaired to create new ones.

Related govmomi bug: <https://github.com/vmware/govmomi/issues/2552>

This workaround is provided by VMware support:

```
1. The issue is fixed in vCenter versions 7.0U2 and above.

2. For lower versions:
Right-click the host, and then select Connection > Disconnect. Next, reconnect, which forces an update of the
VM's portgroup.
```

## SSH connection closed by remote host

For Google Distributed Cloud version 1.7.2 and above, the Ubuntu OS images are hardened with [CIS L1 Server Benchmark](https://docs.cloud.google.com/anthos/clusters/docs/on-prem/1.9/concepts/cis-ubuntu-benchmark).
To meet the CIS rule "5.2.16 Ensure SSH Idle Timeout Interval is configured", `/etc/ssh/sshd_config` has the following settings:

```
ClientAliveInterval 300
ClientAliveCountMax 0
```

The purpose of these settings is to terminate a client session after 5 minutes of idle time. However, the `ClientAliveCountMax 0` value causes
unexpected behavior. When you use the ssh session on the admin workstation, or a cluster node, the SSH connection might be disconnected
even your ssh client is not idle, such as when running a time-consuming command, and your command could get terminated with the following message:

```
Connection to [IP] closed by remote host.
Connection to [IP] closed.
```

As a workaround, you can either:

- Use `nohup` to prevent your command being terminated on SSH disconnection,

  ```
  nohup gkectl upgrade admin --config admin-cluster.yaml --kubeconfig kubeconfig
  ```
- Update the `sshd_config` to use a non-zero `ClientAliveCountMax` value.
  The CIS rule recommends to use a value less than 3.

  ```
  sudo sed -i 's/ClientAliveCountMax 0/ClientAliveCountMax 1/g' /etc/ssh/sshd_config
  sudo systemctl restart sshd
  ```

  Make sure you reconnect your ssh session.

## Conflict with `cert-manager` when upgrading to version 1.9.0 or 1.9.1

If you have your own `cert-manager` installation with Google Distributed Cloud, you might experience a failure when you attempt to upgrade to versions 1.9.0 or 1.9.1. This is a result of a conflict between your version of `cert-manager`, which is likely installed in the `cert-manager` namespace, and the `monitoring-operator` version.

If you try to install another copy of `cert-manager` after upgrading to Google Distributed Cloud version 1.9.0 or 1.9.1, the installation might fail due to a conflict with the existing one managed by `monitoring-operator`.

The `metrics-ca` cluster issuer, which control-plane and observability components rely on for creation and rotation of cert secrets, requires a `metrics-ca` cert secret to be stored in the cluster resource namespace. This namespace is `kube-system` for the monitoring-operator installation, and likely to be `cert-manager` for your installation.

If you have experienced an installation failure, follow these steps to upgrade successfully to version 1.9.0 and 1.9.1:

> [!NOTE]
> **Note:** You only need to apply this work around once for each cluster, and the changes will be preserved across cluster upgrade.

### Avoid conflicts during upgrade

1. Uninstall your version of `cert-manager`. If you defined your own resources, you may want to [backup](https://cert-manager.io/docs/tutorials/backup/#backup) them.

2. Perform the [upgrade](https://docs.cloud.google.com/anthos/clusters/docs/on-prem/1.9/how-to/upgrading).

3. Follow the following instructions to restore your own `cert-manager`.

### Restore your own cert-manager in user clusters

- Scale the `monitoring-operator` deployment to 0.

  ```
  kubectl --kubeconfig ADMIN_CLUSTER_KUBECONFIG -n USER_CLUSTER_NAME scale deployment monitoring-operator --replicas=0
  ```

  <br />

- Scale the `cert-manager` deployments managed by `monitoring-operator` to 0.

  <br />

  ```
  kubectl --kubeconfig USER_CLUSTER_KUBECONFIG -n kube-system scale deployment cert-manager --replicas=0
  kubectl --kubeconfig USER_CLUSTER_KUBECONFIG -n kube-system scale deployment cert-manager-cainjector --replicas=0
  kubectl --kubeconfig USER_CLUSTER_KUBECONFIG -n kube-system scale deployment cert-manager-webhook --replicas=0
    
  ```

  <br />

- [Reinstall `cert-manager`](https://docs.cloud.google.com/apigee/docs/hybrid/v1.9/install-cert-manager).

- [Restore your customized resources](https://cert-manager.io/docs/tutorials/backup/#restore) if you have them.

- Copy the `metrics-ca` cert-manager.io/v1 Certificate and the `metrics-pki.cluster.local` Issuer resources from `kube-system` to the cluster resource namespace of your installed cert-manager. Your installed cert-manager namespace is `cert-manager` if using the [upstream default cert-manager installation](https://cert-manager.io/docs/installation/#default-static-install), but that depends on your installation.

  <br />

  ```
  relevant_fields='
  {
  apiVersion: .apiVersion,
  kind: .kind,
  metadata: {
  name: .metadata.name,
  namespace: "YOUR_INSTALLED_CERT_MANAGER_NAMESPACE"
  },
  spec: .spec
  }
  '
  f1=$(mktemp)
  f2=$(mktemp)
  kubectl --kubeconfig USER_CLUSTER_KUBECONFIG get issuer -n kube-system metrics-pki.cluster.local -o json | jq "${relevant_fields}" > $f1
  kubectl --kubeconfig USER_CLUSTER_KUBECONFIG get certificate -n kube-system metrics-ca -o json | jq "${relevant_fields}" > $f2
  kubectl apply --kubeconfig USER_CLUSTER_KUBECONFIG -f $f1
  kubectl apply --kubeconfig USER_CLUSTER_KUBECONFIG -f $f2
   
  ```

  <br />

### Restore your own cert-manager in admin clusters

In general, you shouldn't need to re-install cert-manager in admin clusters because admin clusters only run Google Distributed Cloud control plane workloads. In the rare cases that you also need to install your own cert-manager in admin clusters, please follow the following instructions to avoid conflicts. Please note, if you are an **Apigee** customer and you only need cert-manager for **Apigee**, you do not need to run the admin cluster commands.

- Scale the `monitoring-operator` deployment to 0.

  ```
  kubectl --kubeconfig ADMIN_CLUSTER_KUBECONFIG -n kube-system scale deployment monitoring-operator --replicas=0
  ```

  <br />

- Scale the `cert-manager` deployments managed by `monitoring-operator` to 0.

  <br />

  ```
  kubectl --kubeconfig ADMIN_CLUSTER_KUBECONFIG -n kube-system scale deployment cert-manager --replicas=0
  kubectl --kubeconfig ADMIN_CLUSTER_KUBECONFIG -n kube-system scale deployment cert-manager-cainjector --replicas=0
  kubectl --kubeconfig ADMIN_CLUSTER_KUBECONFIG -n kube-system scale deployment cert-manager-webhook --replicas=0
    
  ```

  <br />

- Reinstall the customer's `cert-manager`. [Restore your customized resources](https://cert-manager.io/docs/tutorials/backup/#restore) if you have.

- Copy the `metrics-ca` cert-manager.io/v1 Certificate and the `metrics-pki.cluster.local` Issuer resources from `kube-system` to the cluster resource namespace of your installed cert-manager. Your installed cert-manager namespace is `cert-manager` if using the [upstream default cert-manager installation](https://cert-manager.io/docs/installation/#default-static-install), but that depends on your installation.

  <br />

  ```
  relevant_fields='
  {
  apiVersion: .apiVersion,
  kind: .kind,
  metadata: {
  name: .metadata.name,
  namespace: "YOUR_INSTALLED_CERT_MANAGER_NAMESPACE"
  },
  spec: .spec
  }
  '
  f3=$(mktemp)
  f4=$(mktemp)
  kubectl --kubeconfig ADMIN_CLUSTER_KUBECONFIG get issuer -n kube-system metrics-pki.cluster.local -o json | jq "${relevant_fields}" > $f3
  kubectl --kubeconfig ADMIN_CLUSTER_KUBECONFIG get certificate -n kube-system metrics-ca -o json | jq "${relevant_fields}" > $f4
  kubectl apply --kubeconfig ADMIN_CLUSTER_KUBECONFIG -f $f3
  kubectl apply --kubeconfig ADMIN_CLUSTER_KUBECONFIG -f $f4
   
  ```

  <br />

## Conflict with `cert-manager` when upgrading to version 1.9.2 or above

In 1.9.2 or above releases, `monitoring-operator` will install cert-manager in the `cert-manager` namespace. If for certain reasons, you need to install your own cert-manager, please follow the following instructions to avoid conflicts:

> [!NOTE]
> **Note:** One common symptom of installing your own `cert-manager` is that the `cert-manager` version or image (for example v1.7.2) may revert back to its older version. This is caused by `monitoring-operator` trying to reconcile the `cert-manager`, and reverting the version in the process.

> [!NOTE]
> **Note:** You only need to apply this work around once for each cluster, and the changes will be preserved across cluster upgrade.

### Avoid conflicts during upgrade

1. Uninstall your version of `cert-manager`. If you defined your own resources, you may want to [backup](https://cert-manager.io/docs/tutorials/backup/#backup) them.

2. Perform the [upgrade](https://docs.cloud.google.com/anthos/clusters/docs/on-prem/1.9/how-to/upgrading).

3. Follow the following instructions to restore your own `cert-manager`.

### Restore your own cert-manager in user clusters

- Scale the `monitoring-operator` deployment to 0.

  ```
  kubectl --kubeconfig ADMIN_CLUSTER_KUBECONFIG -n USER_CLUSTER_NAME scale deployment monitoring-operator --replicas=0
  ```

  <br />

- Scale the `cert-manager` deployments managed by `monitoring-operator` to 0.

  <br />

  ```
  kubectl --kubeconfig USER_CLUSTER_KUBECONFIG -n cert-manager scale deployment cert-manager --replicas=0
  kubectl --kubeconfig USER_CLUSTER_KUBECONFIG -n cert-manager scale deployment cert-manager-cainjector --replicas=0
  kubectl --kubeconfig USER_CLUSTER_KUBECONFIG -n cert-manager scale deployment cert-manager-webhook --replicas=0
    
  ```

  <br />

- Reinstall the customer's `cert-manager`. [Restore your customized resources](https://cert-manager.io/docs/tutorials/backup/#restore) if you have.

- You can skip this step if you are using [upstream default cert-manager installation](https://cert-manager.io/docs/installation/#default-static-install), or you are sure your cert-manager is installed in the `cert-manager` namespace. Otherwise, copy the `metrics-ca` cert-manager.io/v1 Certificate and the `metrics-pki.cluster.local` Issuer resources from `cert-manager` to the cluster resource namespace of your installed cert-manager.

  <br />

  ```
  relevant_fields='
  {
  apiVersion: .apiVersion,
  kind: .kind,
  metadata: {
  name: .metadata.name,
  namespace: "YOUR_INSTALLED_CERT_MANAGER_NAMESPACE"
  },
  spec: .spec
  }
  '
  f1=$(mktemp)
  f2=$(mktemp)
  kubectl --kubeconfig USER_CLUSTER_KUBECONFIG get issuer -n cert-manager metrics-pki.cluster.local -o json | jq "${relevant_fields}" > $f1
  kubectl --kubeconfig USER_CLUSTER_KUBECONFIG get certificate -n cert-manager metrics-ca -o json | jq "${relevant_fields}" > $f2
  kubectl apply --kubeconfig USER_CLUSTER_KUBECONFIG -f $f1
  kubectl apply --kubeconfig USER_CLUSTER_KUBECONFIG -f $f2
   
  ```

  <br />

### Restore your own cert-manager in admin clusters

In general, you shouldn't need to re-install cert-manager in admin clusters because admin clusters only run Google Distributed Cloud control plane workloads. In the rare cases that you also need to install your own cert-manager in admin clusters, please follow the following instructions to avoid conflicts. Please note, if you are an **Apigee** customer and you only need cert-manager for **Apigee**, you do not need to run the admin cluster commands.

- Scale the `monitoring-operator` deployment to 0.

  ```
  kubectl --kubeconfig ADMIN_CLUSTER_KUBECONFIG -n kube-system scale deployment monitoring-operator --replicas=0
  ```

  <br />

- Scale the `cert-manager` deployments managed by `monitoring-operator` to 0.

  <br />

  ```
  kubectl --kubeconfig ADMIN_CLUSTER_KUBECONFIG -n cert-manager scale deployment cert-manager --replicas=0
  kubectl --kubeconfig ADMIN_CLUSTER_KUBECONFIG -n cert-manager scale deployment cert-manager-cainjector --replicas=0
  kubectl --kubeconfig ADMIN_CLUSTER_KUBECONFIG -n cert-manager scale deployment cert-manager-webhook --replicas=0
    
  ```

  <br />

- Reinstall the customer's `cert-manager`. [Restore your customized resources](https://cert-manager.io/docs/tutorials/backup/#restore) if you have.

- You can skip this step if you are using [upstream default cert-manager installation](https://cert-manager.io/docs/installation/#default-static-install), or you are sure your cert-manager is installed in the `cert-manager` namespace. Otherwise, copy the `metrics-ca` cert-manager.io/v1 Certificate and the `metrics-pki.cluster.local` Issuer resources from `cert-manager` to the cluster resource namespace of your installed cert-manager.

  <br />

  ```
  relevant_fields='
  {
  apiVersion: .apiVersion,
  kind: .kind,
  metadata: {
  name: .metadata.name,
  namespace: "YOUR_INSTALLED_CERT_MANAGER_NAMESPACE"
  },
  spec: .spec
  }
  '
  f3=$(mktemp)
  f4=$(mktemp)
  kubectl --kubeconfig ADMIN_CLUSTER_KUBECONFIG get issuer -n cert-manager metrics-pki.cluster.local -o json | jq "${relevant_fields}" > $f3
  kubectl --kubeconfig ADMIN_CLUSTER_KUBECONFIG get certificate -n cert-manager metrics-ca -o json | jq "${relevant_fields}" > $f4
  kubectl apply --kubeconfig ADMIN_CLUSTER_KUBECONFIG -f $f3
  kubectl apply --kubeconfig ADMIN_CLUSTER_KUBECONFIG -f $f4
   
  ```

  <br />

## False positives in docker, containerd, and runc vulnerability scanning

The docker, containerd, and runc in the Ubuntu OS images shipped with
Google Distributed Cloud are pinned to special versions using [Ubuntu PPA](https://launchpad.net/ubuntu/+ppas).
This ensures that any container runtime changes will be qualified by Google Distributed Cloud before each release.

However, the special versions are unknown to the [Ubuntu CVE Tracker](https://wiki.ubuntu.com/SecurityTeam/UbuntuCVETracker),
which is used as the vulnerability feeds by various CVE scanning tools. Therefore, you will see false positives in docker, containerd, and runc
vulnerability scanning results.

For example, you might see the following false positives from your CVE scanning
results. These CVEs are already fixed in the latest patch versions of Google Distributed Cloud.

- [CVE-2019-16884](https://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2019-16884)
- [CVE-2019-19921](https://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2019-19921)
- [CVE-2020-15157](https://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2020-15157)
- [CVE-2020-15257](https://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2020-15257)

Refer to the [release notes](https://docs.cloud.google.com/anthos/clusters/docs/on-prem/1.9/release-notes) for any CVE fixes.

Canonical is aware of this issue, and the fix is tracked at <https://github.com/canonical/sec-cvescan/issues/73>.

## Unhealthy konnectivity server Pods when using the Seesaw or manual mode load balancer

If you are using Seesaw or the manual mode load balancer, you might notice the konnectivity server Pods are unhealthy. This happens because Seesaw does not support reusing an IP address across a service. For manual mode, creating a load balancer service does not automatically provision the service on your load balancer.

SSH tunneling is enabled in version 1.9 clusters. Thus, even if the konnectivity server is not healthy, you can still use the SSH tunnel, so that the connectivity to and within the cluster should not be affected. Therefore, you do not need to be concerned about these unhealthy Pods.

If you plan to upgrade from version 1.9.0 to 1.9.x, it is recommended you delete the unhealthy konnectivity server deployments before upgrading. Run this command.

```
kubectl --kubeconfig ADMIN_CLUSTER_KUBECONFIG -n USER_CLUSTER_NAME delete Deployment konnectivity-server
```

<br />

## `/etc/cron.daily/aide` CPU and memory spike issue

Starting from Google Distributed Cloud version 1.7.2, the Ubuntu OS images are hardened with [CIS L1 Server Benchmark](https://docs.cloud.google.com/anthos/clusters/docs/on-prem/1.9/concepts/cis-ubuntu-benchmark).

As a result, the cron script `/etc/cron.daily/aide` has been installed so that an `aide` check is scheduled so as to
ensure that the CIS L1 Server rule "1.4.2 Ensure filesystem integrity is regularly checked" is followed.

The cron job runs daily at 6:25 AM UTC. Depending on the number of files on the filesystem,
you may experience CPU and memory usage spikes around that time that are caused by this `aide` process.

If the spikes are affecting your workload, you can disable the daily cron job:

```
`sudo chmod -x /etc/cron.daily/aide`.
```

## Load balancers and NSX-T stateful distributed firewall rules interact unpredictably

When deploying Google Distributed Cloud version 1.9 or later, when the deployment has the Seesaw bundled load balancer in an environment that uses NSX-T stateful distributed firewall rules, `stackdriver-operator` might fail to create `gke-metrics-agent-conf` ConfigMap and cause `gke-connect-agent` Pods to be in a crash loop.

The underlying issue is that the stateful NSX-T distributed firewall rules terminate the connection from a client to the user cluster API server through the Seesaw load balancer because Seesaw uses asymmetric connection flows. The integration issues with NSX-T distributed firewall rules affect all Google Distributed Cloud releases that use Seesaw. You might see similar connection problems on your own applications when they create large Kubernetes objects whose sizes are bigger than 32K. Follow [these instructions](https://docs.cloud.google.com/anthos/clusters/docs/on-prem/1.9/how-to/bundled-load-balance#configuring_stateless_nsx-t_distributed_firewall_policies_for_use_with_seesaw_load_balancer) to disable NSX-T distributed firewall rules, or to use stateless distributed firewall rules for Seesaw VMs.

If your clusters use a manual load balancer, follow [these instructions](https://docs.cloud.google.com/anthos/clusters/docs/on-prem/1.9/how-to/manual-load-balance#resetting_connections_to_failed_nodes_recommended) to configure your load balancer to reset client connections when it detects a backend node failure. Without this configuration, clients of the Kubernetes API server might stop responding for several minutes when a server instance goes down.

## Failure to register admin cluster during creation

If you create an admin cluster for version 1.9.x or 1.10.0, and if the admin cluster fails to register with the provided `gkeConnect` spec during its creation, you will get the following error.

<br />

```
  Failed to create root cluster: failed to register admin cluster: failed to register cluster: failed to apply Hub Membership: Membership API request failed: rpc error: code = PermissionDenied desc = Permission 'gkehub.memberships.get' denied on PROJECT_PATH
  
```

<br />

You will still be able to use this admin cluster, but you will get the following error if you later attempt to upgrade the admin cluster to version 1.10.y.

<br />

```
  failed to migrate to first admin trust chain: failed to parse current version "":
  invalid version: "" failed to migrate to first admin trust chain: failed to parse 
  current version "": invalid version: ""
  
```

<br />

If this error occurs, follow these steps to fix the cluster registration issue. After you do this fix, you can then upgrade your admin cluster.

1. Provide `govc`, the command line interface to vSphere, some variables declaring elements of your vCenter Server and vSphere environment.

   > [!NOTE]
   > **Note:** You can find many of these values in the [admin cluster configuration file](https://docs.cloud.google.com/anthos/clusters/docs/on-prem/1.9/how-to/admin-cluster-configuration-file#vcenter-section) or by logging in to the [vCenter Server](https://docs.vmware.com/en/VMware-vSphere/7.0/com.vmware.vsphere.vcenterhost.doc/GUID-CE128B59-E236-45FF-9976-D134DADC8178.html)

   ```
   export GOVC_URL=https://VCENTER_SERVER_ADDRESS
   export GOVC_USERNAME=VCENTER_SERVER_USERNAME
   export GOVC_PASSWORD=VCENTER_SERVER_PASSWORD
   export GOVC_DATASTORE=VSPHERE_DATASTORE
   export GOVC_DATACENTER=VSPHERE_DATACENTER
   export GOVC_INSECURE=true
   # DATA_DISK_NAME should not include the suffix ".vmdk"
   export DATA_DISK_NAME=DATA_DISK_NAME
   ```

   Replace the following:
   - <var translate="no">VCENTER_SERVER_ADDRESS</var> is your vCenter Server's IP address or hostname.
   - <var translate="no">VCENTER_SERVER_USERNAME</var> is the username of an account that holds the Administrator role or equivalent privileges in vCenter Server.
   - <var translate="no">VCENTER_SERVER_PASSWORD</var> is the vCenter Server account's password.
   - <var translate="no">VSPHERE_DATASTORE</var> is the name of the datastore you've configured in your vSphere environment.
   - <var translate="no">VSPHERE_DATACENTER</var> is the name of the datacenter you've configured in your vSphere environment.
   - <var translate="no">DATA_DISK_NAME</var> is the name of the data disk.
2. Download the <var translate="no">DATA_DISK_NAME‑checkpoint.yaml</var> [file](https://docs.cloud.google.com/anthos/clusters/docs/on-prem/1.9/how-to/create-admin-cluster#managing_the_checkpointyaml_file).

   ```
   govc datastore.download ${DATA_DISK_NAME}-checkpoint.yaml temp-checkpoint.yaml
   ```
3. Edit the checkpoint fields.

   ```
   # Find out the gkeOnPremVersion
   export KUBECONFIG=ADMIN_CLUSTER_KUBECONFIG
   ADMIN_CLUSTER_NAME=$(kubectl get onpremadmincluster -n kube-system --no-headers | awk '{ print $1 }')
   GKE_ON_PREM_VERSION=$(kubectl get onpremadmincluster -n kube-system $ADMIN_CLUSTER_NAME -o=jsonpath='{.spec.gkeOnPremVersion}')

   # Replace the gkeOnPremVersion in temp-checkpoint.yaml
   sed -i "s/gkeonpremversion: \"\"/gkeonpremversion: \"$GKE_ON_PREM_VERSION\"/" temp-checkpoint.yaml

   #The steps below are only needed for upgrading from 1.9x to 1.10x clusters.

   # Find out the provider ID of the admin control-plane VM
   ADMIN_CONTROL_PLANE_MACHINE_NAME=$(kubectl get machines --no-headers | grep master)
   ADMIN_CONTROL_PLANE_PROVIDER_ID=$(kubectl get machines $ADMIN_CONTROL_PLANE_MACHINE_NAME -o=jsonpath='{.spec.providerID}' | sed 's/\//\\\//g')

   # Fill in the providerID field in temp-checkpoint.yaml
   sed -i "s/providerid: null/providerid: \"$ADMIN_CONTROL_PLANE_PROVIDER_ID\"/" temp-checkpoint.yaml

   ```

   Replace <var translate="no">ADMIN_CLUSTER_KUBECONFIG</var> with the path of your admin cluster kubeconfig file.
4. Generate a new checksum.

   - Change the last line of the checkpoint file to

     ```
     checksum:$NEW_CHECKSUM
     ```

     <br />

     Replace <var translate="no">NEW_CHECKSUM</var> with the output of the following command:

     ```
     sha256sum temp-checkpoint.yaml
     ```
5. Upload the new checkpoint file.

   ```
   govc datastore.upload temp-checkpoint.yaml ${DATA_DISK_NAME}-checkpoint.yaml
   ```

## Using Anthos Identity Service can cause the Connect Agent to restart unpredictably

If you are using the [Anthos Identity Service](https://docs.cloud.google.com/anthos/clusters/docs/on-prem/1.9/concepts/authentication) feature to manage [Anthos Identity Service ClientConfig](https://cloud.google.com/anthos/identity/setup/fleet-cluster), the [Connect Agent](https://cloud.google.com/anthos/multicluster-management/connect/overview#agent) might restart unexpectedly.

If you have experienced this issue with an existing cluster, you can do one of the following:

- Disable Anthos Identity Service (AIS). If you disable AIS, that will not remove the deployed AIS binary or remove AIS ClientConfig. To disable AIS, run this command:

  ```
  gcloud beta container hub identity-service disable --project PROJECT_NAME
  ```

  Replace <var translate="no">PROJECT_NAME</var> with the name of the cluster's [fleet host project](https://docs.cloud.google.com/anthos/clusters/docs/on-prem/1.9/how-to/multiple-gcp-projects#fleet_host_project).
- Update the cluster to version 1.9.3, or 1.10.1 or later, so as to upgrade the Connect Agent version.

## High network traffic to monitoring.googleapis.com

You might see high network traffic to monitoring.googleapis.com, even in a
new cluster that has no user workloads.

This issue affects version 1.10.0-1.10.1 and version 1.9.0-1.9.4. This issue is fixed in
version 1.10.2 and 1.9.5.

To fix this issue, upgrade to version 1.10.2/1.9.5 or later.

To mitigate this issue for an earlier version:

1. Scale down `stackdriver-operator`:

   ```
   kubectl --kubeconfig USER_CLUSTER_KUBECONFIG --namespace kube-system \
      scale deployment stackdriver-operator --replicas=0
   ```

   Replace <var translate="no">USER_CLUSTER_KUBECONFIG</var> with the path of the user cluster
   kubeconfig file.
2. Open the `gke-metrics-agent-conf` ConfigMap for editing:

   ```
   kubectl --kubeconfig USER_CLUSTER_KUBECONFIG --namespace kube-system \
      edit configmap gke-metrics-agent-conf
   ```
3. Increase the probe interval from 0.1 seconds to 13 seconds:

   ```
   processors:
     disk_buffer/metrics:
       backend_endpoint: https://monitoring.googleapis.com:443
       buffer_dir: /metrics-data/nsq-metrics-metrics
       probe_interval: 13s
       retention_size_mib: 6144
    disk_buffer/self:
       backend_endpoint: https://monitoring.googleapis.com:443
       buffer_dir: /metrics-data/nsq-metrics-self
       probe_interval: 13s
       retention_size_mib: 200
     disk_buffer/uptime:
       backend_endpoint: https://monitoring.googleapis.com:443
       buffer_dir: /metrics-data/nsq-metrics-uptime
       probe_interval: 13s
       retention_size_mib: 200
   ```
4. Close the editing session.

5. Change `gke-metrics-agent` DaemonSet version to 1.1.0-anthos.8:

   ```
   kubectl --kubeconfig USER_CLUSTER_KUBECONFIG --namespace kube-system \
      edit daemonset gke-metrics-agent
   ```

   ```
   image: gcr.io/gke-on-prem-release/gke-metrics-agent:1.1.0-anthos.8 # use 1.1.0-anthos.8
   imagePullPolicy: IfNotPresent
   name: gke-metrics-agent
   ```

## Missing metrics on some nodes

You might find that the following metrics are missing on some, but not all, nodes:

- `kubernetes.io/anthos/container_memory_working_set_bytes`
- `kubernetes.io/anthos/container_cpu_usage_seconds_total`
- `kubernetes.io/anthos/container_network_receive_bytes_total`

To fix this issue:

- \[version 1.9.5+\]: increase cpu for gke-metrics-agent by following steps 1 - 4
- \[version 1.9.0-1.9.4\]: follow steps 1 - 9

1. Open your `stackdriver` resource for editing:

   ```
   kubectl --kubeconfig USER_CLUSTER_KUBECONFIG --namespace kube-system edit stackdriver stackdriver
   ```
2. To increase the CPU request for `gke-metrics-agent` from `10m` to `50m`,
   add the following `resourceAttrOverride` section to the `stackdriver`
   manifest :

       spec:
         resourceAttrOverride:
           gke-metrics-agent/gke-metrics-agent:
             limits:
               cpu: 100m
               memory: 4608Mi
             requests:
               cpu: 50m
               memory: 200Mi

   Your edited resource should look similar to the following:

       spec:
         anthosDistribution: on-prem
         clusterLocation: us-west1-a
         clusterName: my-cluster
         enableStackdriverForApplications: true
         gcpServiceAccountSecretName: ...
         optimizedMetrics: true
         portable: true
         projectID: my-project-191923
         proxyConfigSecretName: ...
         resourceAttrOverride:
       gke-metrics-agent/gke-metrics-agent:
       limits:
       cpu: 100m
       memory: 4608Mi
       requests:
       cpu: 50m
       memory: 200Mi

3. Save your changes and close the text editor.

4. To verify your changes have taken effect, run the following command:

   ```
   kubectl --kubeconfig USER_CLUSTER_KUBECONFIG --namespace kube-system get daemonset gke-metrics-agent -o yaml | grep "cpu: 50m"
   ```

   The command finds `cpu: 50m` if your edits have taken effect.
5. To prevent your following changes from reverting, scale down `stackdriver-operator`:

   ```
   kubectl --kubeconfig USER_CLUSTER_KUBECONFIG --namespace kube-system scale deploy stackdriver-operator --replicas=0
   ```
6. Open `gke-metrics-agent-conf` for editing:

   ```
   kubectl --kubeconfig USER_CLUSTER_KUBECONFIG --namespace kube-system edit configmap gke-metrics-agent-conf
   ```
7. Edit the configuration to change all instances of `probe_interval: 0.1s` to
   `probe_interval: 13s`:

        183     processors:
        184       disk_buffer/metrics:
        185         backend_endpoint: https://monitoring.googleapis.com:443
        186         buffer_dir: /metrics-data/nsq-metrics-metrics
        187 probe_interval: 13s
        188         retention_size_mib: 6144
        189       disk_buffer/self:
        190         backend_endpoint: https://monitoring.googleapis.com:443
        191         buffer_dir: /metrics-data/nsq-metrics-self
        192 probe_interval: 13s
        193         retention_size_mib: 200
        194       disk_buffer/uptime:
        195         backend_endpoint: https://monitoring.googleapis.com:443
        196         buffer_dir: /metrics-data/nsq-metrics-uptime
        197 probe_interval: 13s
        198         retention_size_mib: 200

8. Save your changes and close the text editor.

9. Change `gke-metrics-agent` DaemonSet version to 1.1.0-anthos.8:

   ```
   kubectl --kubeconfig USER_CLUSTER_KUBECONFIG --namespace kube-system \
      edit daemonset gke-metrics-agent
   ```

   ```
   image: gcr.io/gke-on-prem-release/gke-metrics-agent:1.1.0-anthos.8 # use 1.1.0-anthos.8
   imagePullPolicy: IfNotPresent
   name: gke-metrics-agent
   ```

## Cisco ACI doesn't work with Direct Server Return (DSR)

Seesaw runs in DSR mode, and by default it doesn't work in Cisco ACI because of data-plane IP learning. A possible workaround is to disable IP learning by adding the Seesaw IP address as a L4-L7 Virtual IP in the Cisco Application Policy Infrastructure Controller (APIC).

You can configure the L4-L7 Virtual IP option by going to **Tenant \> Application Profiles \> Application EPGs** or **uSeg EPGs**. Failure to disable IP learning will result in IP endpoint flapping between different locations in the Cisco API fabric.

## gkectl diagnose checking certificates failure

If your work station does not have access to user cluster worker nodes, it will get the following failures when running `gkectl diagnose`, it is safe to ignore them.

    Checking user cluster certificates...FAILURE
        Reason: 3 user cluster certificates error(s).
        Unhealthy Resources:
        Node kubelet CA and certificate on node xxx: failed to verify kubelet certificate on node xxx: dial tcp xxx.xxx.xxx.xxx:10250: connect: connection timed out
        Node kubelet CA and certificate on node xxx: failed to verify kubelet certificate on node xxx: dial tcp xxx.xxx.xxx.xxx:10250: connect: connection timed out
        Node kubelet CA and certificate on node xxx: failed to verify kubelet certificate on node xxx: dial tcp xxx.xxx.xxx.xxx:10250: connect: connection timed out